Kirkas Tech Ventures
Kirkas Tech Ventures
ISO 14001:2015
Nagercoil, Kanyakumari, Tamil Nadu
SEND SMS
SEND EMAIL

New Items

ESE Lightning Arrester

ESE Lightning Arrester
  • ESE Lightning Arrester
Get Best Quote
Approx. Price: Rs 2,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Arrester TypeLightning Rod
MaterialStainless Steel
Poles Number1 Pole
Usage/ApplicationLightning Protection
ClassificationExternal Protection
Discharge Current100 KA

ESE Lightning Protection for Rooftop Solar PV Systems

External lightning protection system design & installation is not a common practice for solar farms. The lightning protection of solar arrays by traditional franklin air terminals is still subject to concern regarding its effectiveness, shadow effect, installation cost, and appearance. As an alternative to the traditional franklin rod system, Early Streamer Emitter (ESE) type lightning air terminal may be utilized to protect rooftop solar pv systems and larger solar farm area.

 

Umbraeco-15 ESE terminal provides large protection zones as per National French standard NF C 17-102 (2011). The principle of operation of Umbraeco-15 ESE terminal is to create an upward propagating streamer earlier than conventional air terminals or other objects on the earth. Umbraeco-15 ESEAT does this by collecting and storing ground charge during the initial phase of a thunderstorm development. Once a thunderstorm begins creating downward step leaders, the ambient electric field intensity in the area of the ESE terminal increases. When thus electric field intensifies, it triggers the terminal to release the ground charge, forming an upward streamer microseconds earlier than other objects in the immediate area. This development of an upward streamer earlier in time and space ensures that the Umbraeco-1e ESE air terminal will be the target of the developing lightning strike.

 

This ESE configuration provides necessary protection zones, effectively dissipate the lightning energy to ground, and helps to insulate the solar panels and inverter/PVCS stations from damage. The other benefit of this system is that there will likely be significantly lower cost of labor, and material to install the entire system as compared to traditional franklin rod system.

Request
Callback


Additional Information:

  • Item Code: ESEAT
  • Production Capacity: 1000 pcs per month
  • Delivery Time: Immediate
Yes! I am Interested
View PDF

Early Streamer Emission

Early Streamer Emission
  • Early Streamer Emission
Get Best Quote
Approx. Price: Rs 3,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Arrester TypeEarly Streamer Emission
MaterialStainless Steel
Poles NumberAir Terminal
Usage/ApplicationDirect Lightning Strike Protection
ClassificationExternal Protection
ColorStainless Steel
Grounding Resistance10 ohms
Discharge Current100 KA

ESE Lightning Protection for Rooftop Solar PV Systems

External lightning protection system design & installation is not a common practice for solar farms. The lightning protection of solar arrays by traditional franklin air terminals is still subject to concern regarding its effectiveness, shadow effect, installation cost, and appearance. As an alternative to the traditional franklin rod system, Early Streamer Emitter (ESE) type lightning air terminal may be utilized to protect rooftop solar pv systems and larger solar farm area.

 

Umbraeco-15 ESE terminal provides large protection zones as per National French standard NF C 17-102 (2011). The principle of operation of Umbraeco-15 ESE terminal is to create an upward propagating streamer earlier than conventional air terminals or other objects on the earth. Umbraeco-15 ESEAT does this by collecting and storing ground charge during the initial phase of a thunderstorm development. Once a thunderstorm begins creating downward step leaders, the ambient electric field intensity in the area of the ESE terminal increases. When thus electric field intensifies, it triggers the terminal to release the ground charge, forming an upward streamer microseconds earlier than other objects in the immediate area. This development of an upward streamer earlier in time and space ensures that the Umbraeco-1e ESE air terminal will be the target of the developing lightning strike.

 

This ESE configuration provides necessary protection zones, effectively dissipate the lightning energy to ground, and helps to insulate the solar panels and inverter/PVCS stations from damage. The other benefit of this system is that there will likely be significantly lower cost of labor, and material to install the entire system as compared to traditional franklin rod system.

Request
Callback


Additional Information:

  • Item Code: ESE
  • Production Capacity: 1000 pcs per month
  • Delivery Time: Ex stock
Yes! I am Interested
View PDF

Roof Top Solar Lightning Protection

Roof Top Solar Lightning Protection
  • Roof Top Solar Lightning Protection
Get Best Quote
Approx. Price: Rs 1,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Usage/ApplicationRoof Top Solar
BrandTOPBAS
Lighting Protection MaterialStainless Steel
ColorSilver
Mast Height5 mtrs
Power SourceNot required

ESE Lightning Protection for Rooftop Solar PV Systems

External lightning protection system design & installation is not a common practice for solar farms. The lightning protection of solar arrays by traditional franklin air terminals is still subject to concern regarding its effectiveness, shadow effect, installation cost, and appearance. As an alternative to the traditional franklin rod system, Early Streamer Emitter (ESE) type lightning air terminal may be utilized to protect rooftop solar pv systems and larger solar farm area.

 

Umbraeco-15 ESE terminal provides large protection zones as per National French standard NF C 17-102 (2011). The principle of operation of Umbraeco-15 ESE terminal is to create an upward propagating streamer earlier than conventional air terminals or other objects on the earth. Umbraeco-15 ESEAT does this by collecting and storing ground charge during the initial phase of a thunderstorm development. Once a thunderstorm begins creating downward step leaders, the ambient electric field intensity in the area of the ESE terminal increases. When thus electric field intensifies, it triggers the terminal to release the ground charge, forming an upward streamer microseconds earlier than other objects in the immediate area. This development of an upward streamer earlier in time and space ensures that the Umbraeco-1e ESE air terminal will be the target of the developing lightning strike.

 

This ESE configuration provides necessary protection zones, effectively dissipate the lightning energy to ground, and helps to insulate the solar panels and inverter/PVCS stations from damage. The other benefit of this system is that there will likely be significantly lower cost of labor, and material to install the entire system as compared to traditional franklin rod system.

Request
Callback


Additional Information:

  • Delivery Time: Ex stock
Yes! I am Interested
View PDF

Umbraeco-15 ESE Air Terminal

Umbraeco-15 ESE Air Terminal
  • Umbraeco-15 ESE Air Terminal
Get Best Quote
Approx. Price: Rs 20,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Arrester TypeESE Lightning Arrester
MaterialStainless Steel
Poles NumberESE Air Terminal
Usage/ApplicationProtection for Direct Strike Lightning
ClassificationExternal Lightning Protection
Discharge Current100 KA

ESE Lightning Protection for Rooftop Solar PV Systems

 

External lightning protection system design & installation is not a common practice for solar farms. The lightning protection of solar arrays by traditional franklin air terminals is still subject to concern regarding its effectiveness, shadow effect, installation cost, and appearance. As an alternative to the traditional franklin rod system, Early Streamer Emitter (ESE) type lightning air terminal may be utilized to protect rooftop solar pv systems and larger solar farm area.

 

Umbraeco-15 ESE terminal provides large protection zones as per National French standard NF C 17-102 (2011). The principle of operation of Umbraeco-15 ESE terminal is to create an upward propagating streamer earlier than conventional air terminals or other objects on the earth. Umbraeco-15 ESEAT does this by collecting and storing ground charge during the initial phase of a thunderstorm development. Once a thunderstorm begins creating downward step leaders, the ambient electric field intensity in the area of the ESE terminal increases. When thus electric field intensifies, it triggers the terminal to release the ground charge, forming an upward streamer microseconds earlier than other objects in the immediate area. This development of an upward streamer earlier in time and space ensures that the Umbraeco-1e ESE air terminal will be the target of the developing lightning strike.

 

This ESE configuration provides necessary protection zones, effectively dissipate the lightning energy to ground, and helps to insulate the solar panels and inverter/PVCS stations from damage. The other benefit of this system is that there will likely be significantly lower cost of labor, and material to install the entire system as compared to traditional franklin rod system.

Request
Callback


Additional Information:

  • Delivery Time: Immediate
Yes! I am Interested
View PDF

Advance Lightning Protection

Advance Lightning Protection
  • Advance Lightning Protection
Get Best Quote
Approx. Price: Rs 5,000 / PieceGet Latest Price

Product Details:

Minimum Order Quantity1 Piece
Usage/ApplicationLightning Protection
BrandLYRA
Lighting Protection MaterialStainless teel
Mast Height2 to 5 mtrs
Power SourceNot required

ESE Lightning Protection for Rooftop Solar PV Systems

External lightning protection system design & installation is not a common practice for solar farms. The lightning protection of solar arrays by traditional franklin air terminals is still subject to concern regarding its effectiveness, shadow effect, installation cost, and appearance. As an alternative to the traditional franklin rod system, Early Streamer Emitter (ESE) type lightning air terminal may be utilized to protect rooftop solar pv systems and larger solar farm area.

 

Umbraeco-15 ESE terminal provides large protection zones as per National French standard NF C 17-102 (2011). The principle of operation of Umbraeco-15 ESE terminal is to create an upward propagating streamer earlier than conventional air terminals or other objects on the earth. Umbraeco-15 ESEAT does this by collecting and storing ground charge during the initial phase of a thunderstorm development. Once a thunderstorm begins creating downward step leaders, the ambient electric field intensity in the area of the ESE terminal increases. When thus electric field intensifies, it triggers the terminal to release the ground charge, forming an upward streamer microseconds earlier than other objects in the immediate area. This development of an upward streamer earlier in time and space ensures that the Umbraeco-1e ESE air terminal will be the target of the developing lightning strike.

 

This ESE configuration provides necessary protection zones, effectively dissipate the lightning energy to ground, and helps to insulate the solar panels and inverter/PVCS stations from damage. The other benefit of this system is that there will likely be significantly lower cost of labor, and material to install the entire system as compared to traditional franklin rod system.

Request
Callback


Additional Information:

  • Delivery Time: Immediate
Yes! I am Interested
View PDF

Solar Grounding System

Solar Grounding System
  • Solar Grounding System
Get Best Quote
Approx. Price: Rs 100 / PieceGet Latest Price
Earthing / Grounding

Grounding is the most fundamental technique for protection against lightning damage. You can’t stop a lightning surge, but you can give it a direct path to ground that bypasses your valuable equipment, and safely discharges the surge into the earth. Good earthings of lightning protection systems shall be able to withstand lightning currents and to disperse them quick and safely.

Each down conductor must have a dedicated earth termination system, formed by conductive elements in contact with the soil and able to disperse the lightning current in it. One earth termination per down conductor and minimum two electrodes / pits per termination is strongly recommended. For the lightning protection earthing, it is preferable to use vertical electrodes, 2 to 3 meters long, forming a triangle since this is the most adequate configuration for dispersing the impulse current of lightning as fast as possible.

Compliance to NF C 17-102 (2011) standard requires an earth DC resistance of 10 ohms for the lightning protection system. Copper bonded rods are preferred for the earthing system. Copper bonded earth rods made from high tensile low carbon steel with the molecular bonding of 99% pure electrolytic copper is generally used for the better conductivity and long life. To improve the soil conductivity (in turn reduce the soli resistance), grounding minerals are used along with the earth rods.
Request
Callback


Additional Information:

  • Minimum Order Quantity: 1 Piece
Yes! I am Interested

Copper Lightning Arrester

Copper Lightning Arrester
  • Copper Lightning Arrester
Get Best Quote
Approx. Price: Rs 500 / PieceGet Latest Price

Product Details:

Length Of Rod1 mtr
Thicknesss10 mm
MaterialCopper
ColorCopper
Diameter10 mm

Request
Callback


Additional Information:

  • Item Code: LA
Yes! I am Interested

Digital Lightning Strike Counter

Digital Lightning Strike Counter
  • Digital Lightning Strike Counter
Ask For Price
Product Price :Get Latest Price
TOPBAS GRUP (Turkey) developed ARES lightning strike counter with a testing jack. ARES LSC is simply mounted at any location along the downconductor route. Its purpose is to record the number of strikes captured and conveyed by the downconductor. When the lightning rod receive an impact of the lightning strike, discharge counter detects the energy dissipated by the down conductor, thereby incrementing the number.

ARES LSC operates by sensing current by means of an inductive pick up loop. With the voltage impulse detected by the current transformer (CT) a trigger to the pulse counter then turns the counter to register the lightning event. The equipment does not require either external or internal power supply, as it is electromechanical and uses the power of the induced current dissipated through the down conductor.

Features

6 digits upto 999,999 counts
IP 67 enclosure testable using tester

Description

ARES Lightning Strike Counter tested for 100 KA lightning impulse current in a transparent polyplastic enclosure.
Request
Callback
Yes! I am Interested

Lightning Arrestors

Ask For Price
Yes! I am Interested
X

Explore more products



Reach Us
Sasikumar (Director)
4-10-D-3A, Kurinchi Nagar Melaputheri, Nagercoil
Kanyakumari- 629001, Tamil Nadu, India



Call Us

Share Us

F GT L


Send E-mailSend SMS